If you are in need of additional power for accessories for your Fire-Lite fire panel then the FCPS24FS8. This is a 8 amp remote power supply with a battery charging circuit that can charge up to an 18 amp battery. If you have come to the limits of the power outputs on your main panel, then this will give you what you need to use additional bells, sirens, strobes, etc. This may be used with either a 12 volt or 24 volt system. Specifications:
Primary (AC) Power: FCPS-24FS8: 120 VAC, 60 Hz, 3.2A maximum. FCPS-24FS8/E: 240 VAC, 50 Hz, 1.6A maximum. Wire Size: minimum #14 AWG (2.0mm2) with 600 V insulation. Control Input Circuit: Trigger Input Voltage: 9 to 32 VDC. Trigger Current: 2.0 mA (16 - 32 V); Per Input: 1.0 mA (9 - 16 V). Trouble Contact Rating: 5 A at 24 VDC. Auxiliary Power Output: Specific application power 500 mA maximum. Output Circuits: +24 VDC filtered, regulated. 3.0 A maximum for any one circuit. Total continuous current for all outputs (stand-alone mode): FCPS-24FS8: 6.0 A maximum. Total short-term current for all outputs (NAC expander mode): FCPS-24FS8: 8.0 A maximum.
| |  |  |  |  |  |  |  |  | Features
- UL-Listed Notification Appliance Circuit (NAC) synchronization
using System Sensor, Wheelock, or Gentex Commander2 appliances. Operates as a sync-follower or as a sync-generator (default). Contains two fully-isolated input/control circuits - triggered from FACP NAC (NAC expander mode) or jumped permanently ON (stand-alone mode). Two Class B (Style Y) or Class A (Style Z, with ZNAC-4 module) NACs (circuits 1 & 3) 8-amp full load output, with 3 amps maximum/circuit, in NAC expander mode (UL 864). 6-amp continuous output in stand-alone mode (UL 1481). Compatible with coded inputs; signals passed through. Optional power-supervision relay (EOLR-1). In stand-alone mode, output power circuits may be configured as: resettable, (reset line from FACP required), non-resettable, or a mix of two and two. Fully regulated and filtered power output - optimal for powering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated/filtered power. Power-limiting technology meets UL power-limiting requirements. Form-C normally-closed trouble relay. Fully supervised power supply, battery, and NACs. Selectable earth fault detection. AC trouble report selectable for immediate 2-hour delay. Works with virtually any UL 864 fire alarm control which utilizes an industry-standard reverse-polarity notification circuit (including unfiltered and unregulated bell power). Requires input trigger voltage of 9 - 32 VDC. Self-contained in compact, locking cabinet - 15 H x 14.5 W x 2.75 D (cm: 38.1H x 36.83W x 6.985D). Includes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batteries. Battery charger may be disabled via DIP switch for applications requiring larger batteries. Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.1mm2) wire.
| | |
|