Description
If you looking for a good 2 zone fire panel then the FIL-MS2 is what you'll want to buy. You can use any 2 or 4 wire device with this system. It will accept smoke detectors, pull stations, tamper switches, and varying normally-open devices.

Another nice thing about the FIL-MS2 is that it is compatible with i3 devices such as the System Sensor line of smoke detectors. The i3 devices have drift compensation, maintenance alert features, and freeze warning alert features. The MS2 also has NAC technology and can silence audible devices, such as fire bells, but will continue to let the strobes function.

If you need an economical fire solution that's fully packed with features of higher-end fire panels, then you can't go wrong by choosing the FIL-MS2

Specifications:


AC POWER TB8
MS-2: 120 VAC, 50/60 Hz, 2.3 A.
MS-2E: 240 VAC, 50 Hz, 1.15 A.
Wire Size: Minimum 14 AWG (2.0 mm˛) with 600 V insulation.

BATTERY (SEALED LEAD-ACID ONLY) J8
Maximum charging circuit: normal flat charge 27.6 VCD @
0.8 A.
Maximum battery charger capacity: 18.0 AH battery (two
7.0 AH batteries can be housed in the FACP cabinet. Larger
batteries require a separate battery box such as the Fire Lite
BB-17F).

INITIATING DEVICE CIRCUIT TB3
Alarm zones 1 & 2.
Power-limited circuitry.
Operation: all zones Style B (Class B).
Normal operating voltage: nominal 20 VDC.
Alarm current: 15 mA minimum.
Short-circuit current: 40 mA maximum.
Maximum loop resistance: 100 ohms.
End-of-line resistor: 4.7K ohm, ˝ watt (P/N 71252).
Standby current: 4 mA.
Compatible devices: refer to the Fire Lite Device Compatibility
Document PN 15384 for a complete list of compatible
devices.

NOTIFICATION APPLIANCE CIRCUIT TB2
One NAC.
Power-limited circuitry.
Normal operating voltage: nominal 24 VDC.
Maximum signalling current: 2.5 A total with standard transformer.
End-of-line resistor: 4.7K ohm, ˝ watt (P/N 71252).
Compatible devices: refer to the Fire Lite Device Compatibility
Document PN 15384 for a complete list of compatible
devices.

FORM-C RELAYS
Trouble Relay TB5 (fail-safe).
Alarm Relay TB6.
Relay contact ratings: 2.0 A @ 30 VDC (resistive).

AUXILIARY OUTPUT: RESETTABLE POWER TB1
Operating voltage: nominal 24 VDC.
Maximum available current: 500 mA appropriate for powering
four-wire smoke detectors (see notes).
Power-limited circuitry.

CABINET DIMENSIONS
Door: 15.342 (38.97 cm) high x 14.667 (37.28 cm) wide x
0.375 (0.95 cm) deep.
Backbox: 15.0 (38.10 cm) high x 14.5 (36.83 cm) wide x 3.0
(7.62 cm) deep.
Related Items
Fire-Lite MS10UD7 10 zone Fire Alarm Panel with DACT
Fire-Lite MS10UD7 10 zone Fire Alarm Panel with DACT
Average Rating 0 Review(s)
Your Price: $780.95
Fire-Lite MS5UD3 5 zone Fire Alarm Panel with DACT
Fire-Lite MS5UD3 5 zone Fire Alarm Panel with DACT
Average Rating 0 Review(s)
Your Price: $626.95
Fire-Lite FCPS24FS8 8 amp Power Supply and Battery charger
Fire-Lite FCPS24FS8 8 amp Power Supply and Battery charger
Average Rating 0 Review(s)
Your Price: $388.95
Fire-Lite FCPS24FS6 6amp Power Supply and Battery Charger
Fire-Lite FCPS24FS6 6amp Power Supply and Battery Charger
Average Rating 0 Review(s)
Your Price: $346.95
Fire-Lite MS4 4 zone Fire Alarm Control Panel
Fire-Lite MS4 4 zone Fire Alarm Control Panel
Average Rating 0 Review(s)
Your Price: $367.95
Fire-Lite ANN80 LCD Annunciator
Fire-Lite ANN80 LCD Annunciator
Average Rating 0 Review(s)
Your Price: $229.95
spacer
 
 
spacer
 
 
45 Day Money Back Guarantee